:::: Tunnel Exhaust Simulator ::::
Category : System Engineering
Product Name : Tunnel Exhaust Simulator
Model : SE-TES20
origin : SEWON ENGINEERING CO
Note :
CADALOG DownLoad    
¢º Ventilation of the Tunnel & Subway system

¢º Flow Analysis in Tunnel using two axial exhaust fan

¢º Analysis of the Air Pressure Transient in Tunnel

 

Spec. / Model
SE-TES20
Dimensions
Approx. 590(W) x 1000(H) x 21000(L)mm
M'TL
Perspex Acryl 8t
Al profile 60x60
Tunnel Model
M'TL -Acryl 8t
Fan - dia.60mm x 4sets
Car Model
1/32 Scale Model
Car Test speed
0-20m/s
Mechanism
Motor-1set
Fly wheel-1set
Magnetic clutch-1set
Brake-1set

Control panel

V meter for Main power
A meter for Main power
Speed meter for test car
E/M switch
start/stop switch
Lamp for power
sequence circuits
Smoke Generator
Capacity-Approx 10L/min
Pressure Range-0.5kg/cm
Compressor-40W
Nozzle-0 20mm x 1ea